HLC-4XU02CY(4P/30A/208-240V) DEFINITE PURPOSE CONTACTOR

$26.00

SKU: 7 Categorías: , Etiqueta:
*Applicable and Description

1. Applicable Scope

HLC-4XU02CY(4P/30A/208-240V) Definite Purpose Contactor(Follow Defers To DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 20A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

     2.Type and Meaning

 

HL C 4X

U

02 CY  
Hongli Electric Contactors

Packaging

Pole Form

Coil Voltage

Contact Rating

Termination

 
“Y” :Individual Box Pack 4X : 4Pole U:208-240VAC 02: FLA 30A CY: #10-32 Combo screw with dual QC  
“-” :Factory Bulk Pack 

*Product Explanation And Main Technical Parameter

Type

HLC-4XU02CY(4P/30A/208-240V) Definite Purpose Contactor

Standard IEC60947 UL508
Rating of Current Ie 30A FLA: 30A
     
Rating of Contacts Voltage Ue 240/277V 240/277/480/600VAC
Rating of Insulation Voltage Ui 660V 600V
Rating of Coil Voltage Us 208-240V  
Mechanical Life 1000,000 Cycle 1000,000 Cycle
Electricity life 100,000 Cycle 250,000 Cycle
Product Explanation

1.Product Description

HLC-4XU02CY(4P/30A/208-240V) Definite Purpose Contactor Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 600v, Fixed Operating Current To 20A Three-Phase Load Circuit Control,At Present, Widely Applies To The Three-Phase Mechanical Device Main Circuit As Well As The Three-Phase Air-Conditioner Compressor Control.

2 .The Regular Service Conditon And Installs The Condition 
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets 
Down The Limiting Value Is -25 
b. The Installation Site Elevation Does Not Surpass 2000m 
c. The Air Pollution Rank Is 2 Levels 
d. Installs The Category Is Ii ; 
e. Installment Facing The Gradient Does Not Surpass ±5° 
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter 
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably 
Working, Its Drop Out Voltage In 20% ~ 70%Us 
b. Contactor Use Category: Ac-1Ac8a 
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor 
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating 
The Breakdown, Behind Check Off May Electrify Tries . 

 

 

*Conforms To The Standard

Conforms To National Standard And International Standard

 

1 Conforms To UL508, IEC60947, GB14048Standard
2 Approved By UL,CUL,TUV,CE,CCC,Safe Certification and ISO9001 System Certification(SGS)

CCC Certificate Number:  2005010309156761

UL Files Number: E251539

*Ordering Request

In Order To Guarantee You Purchase Right, Please Read The Specify Type Before Order. 

Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc

 
If You Request As Follows: Nominal Current: 20A, Working Voltage: 240/277V,480V,600V, Pole Number: Four Pole Without Shunt, Coil Control Voltage:24V, Wiring Way: Quick Connect, Load Current: Three-Phase Motor Controls Or Heating Load, Packing: 25/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-4XU02CY

Lifts The Samples As Follows (Contains Derivation Type From This Model) 

Rating of Current

Ie

Pole Rating of Coil Control Voltage  Control Motor Power
24VAC 120VAC 208/240VAC 277VAC 380/480VAC 240VAC
30A

4P

HLC-4XQ02CY HLC-4XT02CY HLC-4XU02CY HLC-4XV02CY HLC-4XH02CY 5Kw
Peso 0.6 kg

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “HLC-4XU02CY(4P/30A/208-240V) DEFINITE PURPOSE CONTACTOR”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Este sitio usa Akismet para reducir el spam. Aprende cómo se procesan los datos de tus comentarios.

es_MXSpanish
Powered by TranslatePress